New Features
EPTZ
- Added EPTZ (cropping) support to the SuperZoom (BETA) function located in Control > Mode > ZoomModes. The camera can now digitally zoom in and navigate around the image sensor, enabling electronic pan, tilt, zoom, and preset set/recall functionality.
- Note: SuperZoom & EPTZ are only available on the Studio 4K. A reboot is required to enable SuperZoom.
Image Settings
- Added One Push Exposure functionality. When triggered, the camera automatically calibrates exposure settings (shutter speed and gain) based on current lighting conditions, then locks them for manual control, similar to One Push White Balance.
- Added Bright Mode to the Exposure Mode settings.
Camera Features and Security
- Added Focus Calibration to the Web UI under System Settings > Advanced.
- Added Privacy Mode to the Web Interface and provided corresponding VISCA command support:
- 0x81, 0x01, 0x3F, 0x0A, 0x12, 0x0p, 0xFF
- p=1 Privacy Mode Enabled
- p=0 Privacy Mode Disabled
- Added Standby Mode to the Web Interface and provided corresponding VISCA command support:
- 0x81, 0x01, 0x3F, 0x0B, 0x01, 0xAA, 0xFF
- Added the ability to disable IR remote input to enhance security, located in System Settings > IR Remote Channel Selection.
Audio / Video & Interface
- Reorganized the Audio section of the Web UI to improve user experience and accessibility.
Bug Fixes
Streaming & Protocols
- Resolved issue where HX3 enabled mode did not restrict certain settings required by the NDIHX3 certification process.
- Stream 1 Encode Protocols — only H.264 and H.265 are selectable when HX3 is On; MJPEG is unselectable.
PTZ & Control
- Fixed issue where Iris control via ONVIF was inverted — “Open” now correctly opens the iris and “Close” closes it.
- Resolved issue with Pelco D/P protocol presets — presets can now be both saved and recalled using Pelco commands.
- Fixed IR remote shortcut * > * > [F3], which now correctly toggles between SDI and HDMI outputs.
Known Issues
- Enabling NDI HX3 leaves the camera’s refresh rate at its last value; if that isn’t 50 Hz or 60 Hz, the stream may not function as HX3.
- Resolution: Please ensure the refresh rate matches the intended NDI HX3 profile needed.
- With NDI HX3 enabled, the Bitrate can not be edited within the allowable range.
- Resolution: With the HX3 profile toggle set to Off, replicate the HX3 settings (I Key Frame: 20, Bit Rate Control: CBR, Encode Protocol: main) with the desired Bitrate.